Pneumatic Timers > Ellis Kuhnke Surface & Panel Mounted Pneumatic Timers

PT & PMT series Ellis Kuhnke Pneumatic Timers

The Ellis Kuhnke range of pneumatic timers was developed specifically for the US markets, and remains a popular product within the oil industry. The PT is unique in that no air bleed is used to achieve the timing function. The off-delay version is the only product to offer a genuine time delay after removal of compressed air signal. The Timer & Counter Company can supply all Ellis Kuhnke timers worldwide. There are 2 ranges, and each model is built to include the customer's selection of standard features.

The PT Series includes panel and surface mount versions, 9 different time ranges from 0.1 - 1.0 seconds to 6 - 60 minutes. PT series are either on delay (normally closed) or off delay (normally open). PT series operate at low pressures, 5 psi (0.3 bar), up to 140 psi (9.5 bar) with 1/8 NPTF ports.

Data Specifications - PT
Operating Pressure & Temp 0.4 - 9.5 bar (5 - 140 PSI)
-30 ... + 70°C
Control Pressure 0.4 - 9.5 bar (5 - 140 PSI)
Air Quality Oil Free & Dry 5micron filtered
Connections 1/8 NPTF
Time Setting Infinite Through Time Range
Method of Setting Rotary Knob
Accuracy ±10% end scale value
±10% resetting
Air Consumption None
Reset Time 60ms at 3.5bar (50 PSI)

The PMT Series have a clock face with a dial indicator showing set time. It is only available as on delay (normally closed) with 6 time ranges, all below 180 seconds. Available with 10 - 32, 1/8 NPTF ports via a bottom subplate. These are generally supplied as replacement parts. For new applications the Kuhnke 54 series pneumatic timer offers great accuracy.

Data Specifications - PMT
Operating Pressure & Temp 1 - 7 bar (15 - 100 PSI) 0 ... + 65°C
Control Pressure (A) 1 - 7 bar (15 - 100 PSI)
(B)2 - 7 bar (30 - 100 PSI)
Air Quality Oil Free & Dry 5micron filtered
Connections 1/8 NPTF
Time Setting Infinite Through Time Range
Method of Setting Rotary Knob
Accuracy ±10% end scale value
±3% resetting
Air Consumption 0.1cfm @ 100 PSI (3.4l/min @ 7 bar)
Reset Time 60ms at 3.5bar (50 PSI)
Part Numbers
PT41* PT = Model;
3 or 4 = on/off delay;
1 or 5 = surface/panel mount;
* = time range: A = 0.1 - 1.0 seconds; B = 0.5 - 5.0 seconds; C = 1.5 - 15.0 seconds; D = 5.0 - 50.0 seconds; E = 20.0 - 200.0 seconds; F = 1.0 - 10.0 minutes; H = 3.0 - 30.0 minutes; I = 6.0 - 60.0 minutes; K = 1.0 - 300.0 seconds
PMT1*XYZ PMT = Model;
1 = on delay;
* = Time range: D=0.3-3.0 sec; E =1.0-10.0 sec; F=3.0-30.0 sec; G=6.0-60.0 sec; H=12.0-120.0 sec; J= 18.0-180.0 sec
X = Mounting: 1 = Subplate Mount; 2 = Vertical panel mount; 3 = Horizontal panel mount
Y = Pilot pressure actuation range: A = Low Pressure(15-100PSI); B = High Pressure(30-100 PSI)
Z = Manifold position: 1 = Top side; 2 = Right side; 3 = Bottom side; 4 = Left side

PDF Datasheets
PT 31 On-Delay Surface Mount82kb
PT 35 On-Delay Panel Mount76kb
PT 41 Off-Delay Surface Mount79kb
PT 45 Off-Delay Panel Mount77kb
PMT On-Delay - Subplate Mount104kb
PMT On-Delay - Vertical Panel Mount111kb
PMT On-Delay - Horizontal Panel Mount 110kb

Features

For a full list of options and explanation please contact The Timer & Counter Company.


Hengstler © 2007 H. Kuhnke Ltd | Contact | +44 (0)1794 514445
Web Development - Orionesque Ltd
Registered in the UK - No. 665193 - VAT No. GB207766451
Kuhnke

www.thetimerandcountercompany.com | sales@thetimerandcountercompany.com
Tel: +44 (0)1794 514445 | Fax: +44 (0)1794 513514